How To Tighten Electric Fence Wire?

Does electric fence wire need to be tight?

Electric Fences do not have to be tightly strained that a guitar solo may be played on them. Use inline-strainers that pull just enough to get the sag out of the wire between the fence posts and no more. Invariably pulling them up by hand is all that is required.

How do you tension a wire?

Twist the end of the wire together with the rest of the strand. Pull the loop around the post and fold it over the strand of wire. Push your bolt through the loop. Use the lever to twist the loop around the strand of wire and continue twisting until the fence is tight.

Can you tie electric fence wire together?

When joining wires together in the middle of a fenceline use either a figure 8 knot or a reef knot. Wire on an electric fence does not require the same tension as conventional fences. The recommended tension is between 180 – 220lbs (800 – 1000 Newtons).

What can I use to ground my electric fence?

In most cases, pipe or rebar can be used. The grounding rod needs to be made of galvanized steel and also needs to be at least four feet in length for best results. Using copper rods will diminish the overall effectiveness of the electrical fence system.

You might be interested:  How To Make Wood Fence?

Can copper wire be used for electric fence?

We call this a “hot/ground” electric fence. Also, don’t use anything other than galvanized steel in the ground system. Copper components, for example, can cause electrolysis and eventually corrode the system’s connections. Always use a quality galvanized clamp for ground rod AND fence wire connections.

How do I make my electric fence stronger?

If the fence extends over 500m away from the main earth it will be necessary to add an additional earth line to the bottom of the fence and bury a stake at those intervals. Wire is a better conductor than ground so a ground rod every +/- 500meters will greatly increase the effectiveness of the fence.

What size wire do you run to a ground rod?

The NEC code requires that a solid copper wire used to connect to a ground rod be either #6 or #8 gauge, depending on the size of your electrical service cable.

Can a ground wire be bare?

Bare copper grounding wire is less expensive than insulated grounding wire and works well in many industrial applications. Particularly for large projects, using bare copper may yield significant cost savings.

How do I test my electric fence ground?

Testing the Ground System

  1. Turn off the energizer.
  2. At least 330 ft (100 m) away from the energizer, short circuit the fence by laying several steel rods (or lengths of pipe) against the fence.
  3. Turn on the energizer.
  4. Use a digital voltmeter to measure the fence voltage.